WinFluor Updates
WinFluor V4.2.1 21/09/24 Update: Cameras: NimagDX support for USB3 Vision updated (support for mono12p,mono12paccked,mono10p,mono10packed. Tested with FLIR Blackfly camera. |
WinFluor V4.2.0 31/05/24 File Properties: Settings in file header can now be edited on File > Properties page, to allow damgaged file headers to be fixed.
|
WinFluor V4.1.9 10/10/22 Bug Fix: Display Images: Stack overflow (introduced V4.1.8) when IDR data files with no preexisting ROIs defined fixed. |
WinFluor V4.1.7 13/10/21 Bug Fixes: NI Interfaces: +/10V DAC output voltage range now correctly identified in devices which support more than one output range (e.g. USB-6363) |
WinFluor V4.1.6 23/20/20 Bug Fixes: Cameras: Hamamatsu sCMOS cameras. ORCA-Fusion and FLASH 4.0 V3 now correcltly detected as sCMOS cameras and appropriate adjustments to min. frame interval and expsosure time set. |
WinFluor V4.1.5 03/02/20 NI Interfaces: Extra space allocated for A/D channel lists to accommodate devices with large no.s of channels. |
WinFluor V4.1.4 29/01/20 Amplifiers: A-M Systems 2400. Gain telegraph code updated to handle telegraph voltage series 0,0.3,0.8V and 0,0.5,1.0V ... produced by different versions of the amplifier. |
WinFluor V4.1.3 05/12/19
|
WinFluor V4.1.2 22/11/19 Update: Export Files: User can now select folder into which exported files as stored. |
WinFluor V4.1.1 12/11/19 Bug Fix Export Analogue Signals: Select Files to Export and Clear Files buttons now work. |
WinFluor V4.1.0 01/07/19 Bug Fix Users can now change channel name/units/scales in Camera/System Setup Channel Table for channels not selected for use with Amplifier #1 or #2. |
WinFluor V4.0.9 10/06/19 Updates: Light Sources: Sutter Lambda-421 LED liight source now supported. |
WinFluor V4.0.8 18/02/19 Updates: PCO Cameras: Now works with PCO Edge 5.5 with Camera Link interface. |
WinFluor V4.0.7 14/11/18 Updates: Cameras: Support for IDS cameras supported by MicroEYE library added. |
WinFluor V4.0.6 8/10/18 Bug Fix |
WinFluor V4.0.5 29/8/18 Bug Fix Sutter DG-4 Light Source: Digital bit pattern for filters 1-4 now set correctly. Fourth control line added to Setup panel. Support for 50% and 33% attenuated filter settings added. |
WinFluor V4.0.4 28/8/18
|
WinFluor V4.0.3 15/7/18 |
WinFluor V4.0.2 23/4/18 Update NI 628x devices: Digital output lines now supported on NI 628x devices. A/D samples now acquired as double precision floating point values adn converted to 16 bit integer, to allow support of 18 bit A/D devices. |
WinFluor V4.0.1 3/4/18 Bug Fix Photometrics Evolve Delta Camera (LightSpeed mode): Exposure interval can now be set in steps of 0.1 ms, allowing sub-1ms intervals. Frame transfer time now estimated as 10% of exposure interval for intervals less than 10ms to allow highest frame rates to be achieved. |
WinFluor V4.0.0 27/3/18 Bug Fix Photometrics Evolve Delta Camera (LightSpeed mode): Camera now set in ALT_FT mode when LightSpeed option is selected to ensure that overlap readout mode is enabled allowing the highest possible frame rates. |
WinFluor V3.9.9 26/3/18 no longer set to |
WinFluor V3.9.8 18/1/18 Updates Cameras: Lightspeed mode now supported for Photometrics Evolve 512 Delta camera (not tested yet). |
WinFluor V3.9.7 15/1/18 Bug Fixes |
WinFluor V3.9.6 7/1/18 Bug Fixes Record Images & SIgnals: Floating point errors on some systems due to uninitialised floating point plotting buffers fixed, |
WinFluor V3.9.5 27/11/17 Bug Fixes |
WinFluor V3.9.3 7/11/17 Bug Fixes |
WinFluor V3.9.2 02/10/17 Bug Fixes Record Image: Optoscan monochromator now works again. Scroll bar out of range errors blocked. PVCAM cameras: Camera shutter (if present) now opened before start of capture sequence. |
WinFluor V3.9.1 31/7/17 Bug Fixes |
WinFluor V3.9.0 14/7/17 Updates |
WinFluor V3.8.9 11/5/17 Bug Fixes Thorlabs Cameras: Readout Speed now preserved when camera re-opened to avoid being reset to minimum. Setup: 64 bit setup now correctly installs 64 version. |
WinFluor V3.8.8 2/5/17 Bug Fixes Export Images/ROI Time Course/Analogue Signals: Select Files now works. |
WinFluor V3.8.7 8/12/16 Bug Fixes 64 bit version: 64 bit installation file now correctly installs 64 bit version (instead of 32 bit). |
WinFluor V3.8.7 8/12/16 |
WinFluor V3.8.6 16/11/16 Updates: View Images: ROI time course plots now averaged and plotted using floating point values giving more precise plot when pixel grey level signal is small. ROI data is saved in .RTC file to avoid recomputing when files loaded. Cameras: Point Grey Grasshopper 3 now supported (using National Instruments NIMAQdx library). Exports: Export->Multiple files can now be selected for export in Analogue Signals and Export->ROI Time Course. |
WinFluor V3.8.5 11/5/16 Bug Fixes USB-621X boards: Digital outputs marked as not supported to prevent error messages. Record Images & Signals: Additonal floating point divide by zero checks. |
WinFluor V3.8.4 31/3/16 Bug Fix |
WinFluor V3.8.3 11/3/16 Bug Fix |
WinFluor V3.8.2 4/3/16 Bug Fixes |
WinFluor V3.8.0 25/11/15 Bug Fix |
WinFluor V3.7.9 24/11/15 |
WinFluor V3.7.8 19/11/15 |
WinFluor V3.7.7 19/10/15 Bug Fixes Edit->Copy Graph Data: Data compression now implemented again allowing large data records to be copied to the clipboard again. |
WinFluor V3.7.6 12/10/15 Updates Thorlabs cameras: Unsupported is_devicefeatures() error messages now blocked with DCU cameras which do not support shutter modes. Detect Events: Event detection revised. Numerous minor bugs fixed. Record Images & Signals: auto contrast feature now works correctly. |
WinFluor V3.7.5 1/7/15 Updates |
WinFluor V3.7.4 14/5/15 Updates |
WinFluor V3.7.3 9/4/15 Updates Export: Multi-wavelength files exported to separate TIFF files now have option to have matched frame counts. Files padded with with nearest previous frames when a frame is not available to make no, of frames equal to total frames in file.Bug Fixes Record Images & Signals: Real time images should be updated more reliably and auto contrast adjustment should work more reliably. |
WinFluor V3.7.2 18/2/15 Updates XY Stages: Support for Thorlabs MLS203 motorised XY stage added.File Export: Export of ROI and analogue time course to Matlab MAT files now works. Light Sources: Analogue and Digital light source control output channels can now be individually selected and mixed within the same light source. LEDs controlled by analogue outputs can have intensity set from WinFluor control panel. Bug Fixes Sensicam cameras: Changes to image acquisition code to investigate problems occurring with latest sensicam library. |
WinFluor V3.7.1 27/1/15 Updates Record Images & Signals: Reliability of long term recordings increased.Recording is now restarted in time lapse modes if camera drops images or halts. Data file is closed/reopened after each time lapse image to ensure directory information is preserved in the event of a program crash.Time Course Analysis: ROI lines now labelled with ROI number. |
WinFluor V3.6.9 3/12/14 Updates QImagjng Cameras: Absolute m inimum exposure time reduced to 10ms. |
WinFluor V3.6.9 3/12/14 Updates |
WinFluor V3.6.8 23/10/14 Updates |
WinFluor V3.6.7 16/9/14 Bug Fixes: File/Export Images: Files with long file paths no longer generate a "file not found" error preventing export to TIF and other file formats (since V3.5.9). |
WinFluor V3.6.6 16/9/14 Bug Fixes 64 bit version now works with Andor SDK2 cameras. |
WinFluor V3.6.5 5/9/14 Updates Support for Thorlabs DCx series cameras added. Exposure time now adjusted for Emission filter change time when emission filters in use (and no longer needs to be set to zero when filters not in use.). |
WinFluor V3.6.4 9/7/14 Bug Fixes MultiClamp 700: 64 bit version now works correctly. |
WinFluor V3.6.3 9/7/14 Bug Fixes MultiClamp 700: Updated to support V2.X versions of MultiClamp Commander. Updates PVCAM & NIMAQdx: Individual cameras can now be selected when multiple cameras are available on interface. |
WinFluor V3.6.2 9/7/14 Bug Fixes Record windows: Calibration bars now scaled by lens magnification. |
WinFluor V3.6.1 23/6/14 Updates PVCAM: Support for QImaging OptiMOS added. Improvements to CoolSnap support. Real time course plots can now have more than 100000 frames. |
WinFluor V3.6.0 16/5/14 Bug FixesPVCAM: Failure to detect procedures within PVCAM64.DLL on some Windows 7 (64 bit) systems fixed. (Needs to be verified on systems which display this problem.) |
WinFluor V3.5.9 15/4/14 Hamamatsu DCAM: 64 bit support tested and working correctly with FLASH 4.0. Create AVI: Analog time course traces now plotted correctly again in AVI file. |
WinFluor V3.5.8 3/4/14 Updates |
WinFluor V3.5.7 20/2/14 Updates Support for Andor Zyla and Hamamatsu improved, number of bugs and limitations fixed. Larger image buffer size allocated. |
WinFluor V3.5.4 9/11/13 Bug Fix Hamamatsu C4480: Failure to detect .CNF files (since V3.50) now fixed. Should now work correctly with Hamamatsu C4880 camera. |
WinFluor V3.5.2 7/11/13 Z stage: Z stage movements now take place AFTER image (or series of images in multi-wavelength mode) are acquired in time lapse recording mode. In continuous recording mode, Z stage is moved at preset time before end of image acquisition frame. Illumination can be turned off or exposure terminated during Z stage movement period. Z step time defined in Z stage setup. Andor Ixon Cameras: Camera readout noise can now be optimised by adjusting Readout A/D gain and vertical shift timing in Setup/Extra Camera Settings. WinFluor is now compiled using Embarcadero Delphi XE3 development system |
WinFluor V3.4.9 9/7/13 Bug FixesNIDAQ (Traditional) card support: Number of available DMA channels now correctly identified for PCI-6035E and PCI-6052E, avoiding -10455 error with PCI-6035E. |
WinFluor V3.4.8 4/6/13 Bug FixesRecord Images & Signals: Selecting stimulus Start on Record no longer produces "Unable to Load Stimulus" and floating point errors when recording is started and stimulus program is set to None. Stimulus program folder now also selected with SelectDirectory dialog box. |
WinFluor V3.4.7 3/6/13 Updates: |
WinFluor V3.4.6 24/04/13 Bug Fixes Biorad/PraireView recording: Bug fix in NIDAQMX_MemoryToDAC() to avoid access violations when A/D restarted. Real time display sweep now correctly synchronised to incoming signal Stimulus Protocols:Default protocol folder now selected in folder in INI file not found. SelectDirectory() dialog now used to set voltage protocol folder.
|
WinFluor V3.4.5 03/04/13 Record Image & Signals:Image capture now functions when camera triggered by digital line and no analog outputs are in use. Small rectangles at corners of image selection region added to make it more visible. Camera now restarted when excitation turned on/off to speed up change. Camera restarted when new file created. |
WinFluor V3.4.4 30/01/13 Support for voltage-driven piezo Z stage controllers added. Z stacks can now be acquired in Images & Signals recording module. |
WinFluor V3.4.3 14/12/12 Updates: Record Images & Signals:Time Lapse + Burst recoding mode added allowing high speed bursts of image to be acquired during time lapse sequences. Recording duration now specified as time duration rather than number of frames. "Turn on when recording" option added to turn on excitation light when recording starts and off when finished. Bug Fixes: Event Detector:T.90% and decay time constant waveform measurements now calculated correctly. Measurement plots cursor now displays values correctly. Detected events can now be exported to WCP format files without floating point error when loaded into WinWCP (due to incorrect setting of no. of points in baseline average.) |
WinFluor V3.4.0 17/9/12 Bug Fixes: Andor Ixon:Display LUTnolonger maps to black when at maximum intensity of camera. View Images:Memory access violation when ratio plot selected fixed. Contrast auto update setting now retained when window closed. |
WinFluor V3.3.9 31/7/12 Bug Fixes: NIMAQ-dx:Camera frame width and height now set correctly when program started. Updates: Max. number of ROIs increased from 50 to 100. |
WinFluor V3.3.8 30/7/12 Updates:
|
WinFluor V3.3.7 30/4/12 |
WinFluor V3.3.6 6/2/12 Bug Fixes: Record to Disk: User specified number of images isnow saved to file rather than nearest bufferful. Time Lapse: Duration of time lapse interval now correctly restricted to duration of timing waveform buffer. Minimum duration now 2 x frame interval x no. of wavelengths in sequence. Viewing:ROIs can now be dropped on to any image panel in multi-wavelength images not just top-left. ROI time course computation no longer terminates prematurely when files being read from slow disk drives. Update: Support for National Instruments IMAQdx added, supported GIGE, firewire and Video for Windows cameras. |
WinFluor V3.3.4 30/8/11 Bug Fix: Hamamatsu DCAM: Yet another attempt to fix DCAM scan speed problem. |
WinFluor V3.3.3 26/8/11 Bug Fix: Hamamatsu DCAM: Scan speed not corrected in V3.3.2 Additional change to fix DCAM scan speed problem. |
WinFluor V3.3.2 25/8/11 Bug Fix: Hamamatsu DCAM: Camera scan speeds now set correctly when cameras support more than one scan speed. |
WinFluor V3.3.0 27/7/11 |
WinFluor V3.2.3 11/2/11 Bug Fix: QIMaging camera support:Fixed 'camera busy' error which ocurred whenevercertain QImaging cameraswere restarted. |
WinFluor V3.2.27 04/2/11 Updates: Support for Cairn TIRF system added. Latest QImaging cameras now supported. Post exposure CCD readout option added for PVCAM cameras. Control panel added allowing direct control of analog and digital output lines for test purposes. Width of calibration bars can now be adjusted and calibration bar settings retained in INI file. |
WinFluor V3.2.25 15/12/10 PVCAM cameras: Cameras now correctly operate in frame transfer mode, allowing full frame speed of camera to be achieved. |
WinFluor V3.2.24 1/11/10 ROI time course now updated automatically when ROI's added/changed. |
WinFluor V3.2.23 21/10/10 Updates: Event detector: Size of display buffer increased allowing larger time windows to be displayed. Analog filter module added (Analysis/Filter Analog Signals) allowing low/high pass/notch filtering of analog signal channels. Upper limit of live and replay time course window displays increased from 2000s to 20000s. Bug Fixes: Time courses of ROI2 - ROIn can now be exported without being set to zero. Event Detector: Files now exported to WCP data files correctly. |
WinFluor V3.2.21 28/07/10 Updates: Event detector updated. Improved event detection method - threshold relative to a rolling average baseline. Detection now on a separate tab page. NI PCI-1405 frame grabber can now be externally triggered and synchronised to light sources. Bug Fixes: External triggering now works correctly with PVCAM cameras. Bug which caused program to lock up when reading beyond end of IDR data file fixed. Discrepancies between number of image frames in header fileand size of data file now corrected when loading files. |
WinFluor V3.2.19 27/01/10 |
WinFluor V3.2.16 10/9/09 |
WinFluor V3.2.15 22/5/09 |
WinFluor V3.2.14 17/4/09 |
WinFluor V3.2.13 18/3/09 |
WinFluor V3.2.12 18/3/09 Bug Fix Intermittent pauses in frame acquisition in recording window with PVCAM cameras now fixed. |
WinFluor V3.2.9 11/3/09
|
WinFluor V3.2.9 12/3/09 |
WinFluor V3.2.8 17/0 2/09 |
WinFluor V3.2.7 27/01/09 Bug Fix Andor DLL library atmcd32d.dll in c:\winfluor folder now located correctly. |
WinFluor V3.2.6 26/01/09 Bug fixes |
WinFluor V3.2.5 27/08/08
|
WinFluor V3.2.4 06/08/08 Signal time course plots now have better chosen oY axis calibration ticks. Channels can be individually removed from display and resized. |
WinFluor V3.1.8 20/5/08 |
WinFluor V3.0.9 29/8/07 No. of increments in multi-step stimulus protocols no longer reset to one when single step or ramp waveforms edited. |
WinFluor V3.0.8 21/8/07 |
WinFluor V3.06 31/7/07 |
WinFluor V3.05 31/7/07 Updates |